Service Station ULP Fuel Additive Treatment Guide
This guide provides clear recommendations for selecting the appropriate fuel treatment product based on the condition of petrol (ULP) dispensing systems at service stations. Suitable for all fuel delivery systems where pump flow rates may be compromised.
Select the appropriate fuel treatment product based on the condition of petrol (ULP) dispensing systems at service stations.
(Diesel Treatments also available)
- Reduced fuel flow at the bowser
- Filters blocking
- Contaminated fuel
- Varnish
- Tank Debris / Bottom of tank sediments
Fuel System Conditions & Recommended Actions
Normal Operation (Preventative)
Situation:
- No issues with flow or filters
Action:
- Use Cleanpower continuously
Result:
- Keeps system clean
- Prevents buildup
- Reduces maintenance
Early Warning Signs (Act Early)
Situation:
- Pumps starting to slow
- Brown debris seen in filters during routine service
- Flow becoming inconsistent
Action:
- Start or continue Cleanpower
Result:
- Gradual improvement
- Prevents issue getting worse
- No disruption to site
Restricted Flow (No Downtime Option)
Situation:
- Filters starting to block
- Flow reduced but site must keep operating
Action:
- Continue Cleanpower
Result:
- Slower improvement
- Minimal disruption
- May require filter checks
Blocked Filters / Severe Restriction
Situation:
- Filters blocked
- Heavy brown residue
- Significant loss of flow
Action (Step-Up Approach):
- Start with Cleanpower if downtime must be avoided
- If issues persist or faster cleaning is required → use PMX145
- Replace filters as required
Result:
- Cleanpower: gradual improvement with minimal disruption
- PMX145: faster clean-up and restored flow
Water / Microbial Contamination
Situation:
- Water present in tank
- Slime or contamination observed
Action:
- Remove water
- Use Kathon 15
Result:
- Eliminates contamination
Fuel Additive Treatment Guide for Service Station Usage
ULP 91, 95 & 98 (Diesel Additives also available)
| Pump Status | What You See | What To Do | Product | Expected Result |
|---|---|---|---|---|
| Normal | Everything normal | Keep dosing | Cleanpower | System stays clean |
| Warning | Pumps starting to slow | Start treatment | Cleanpower | Flow improves gradually |
| Warning | Brown residue in filters (during service) | Start treatment | Cleanpower | Prevents buildup getting worse |
| Warning | Flow dropping / inconsistent | Continue treatment + monitor filters | Cleanpower | Stabilises system |
| Warning | Filters blocking but cannot stop pumps | Keep running + treat | Cleanpower | Slow improvement, no disruption |
| Severe | Filters blocking / heavy brown residue | Start with Cleanpower → escalate if needed | Cleanpower → PMX145 | Gradual or fast recovery depending on approach |
| Severe | Filters keep blocking | Clean system properly | PMX145 | System resets, then stabilises |
| Contamination | Water in tank | Remove water + treat | Kathon 15 | Eliminates contamination |
| No Improvement | No improvement | Call technician | — | Mechanical issue |
Download ULP Fuel Additive Guide here
Bowser / Filter Check Guide for Additive Use
| Product | When Using It | What To Do With Filters |
|---|---|---|
| Cleanpower | Normal / early issues | No change – check during normal service |
| Cleanpower | Some deposits in system | Check filters more often |
| Cleanpower | Blocked system (keeping pumps running) | Check filters and change if needed |
| PMX145 | Filters already blocked | Change filters immediately |
| PMX145 | First clean on dirty system | Check often – change filters as needed |
| PMX145 | After system is clean | Back to normal filter schedule |
| Kathon 15 | Initial dose (water/microbial contamination) | Check filters and change after initial dose |
| Kathon 15 | Ongoing treatment | Check filters and change if needed |
Additive Dosage & Best Practice
Cleanpower Dosage: 1:4000
PMX145 Dosage: 1:4000
Kathon 15 Dosage: 1:3300
Best Practice Dosing
Dose additives into tanks just prior to or during refuelling to ensure proper mixing.
Review product data sheets for dosing procedures.
- Cleanpower = Preventative + first step treatment
- PMX145 = Escalation for faster corrective cleaning ( Pump down-time may be required)
- Kathon 15 = Only for confirmed water / microbial contamination
Recommended Strategy
- Maintain system with Cleanpower
- At first sign of slowing or brown debris → use Cleanpower
- If filters block → start with Cleanpower, then escalate to PMX145 if required
- Only use Kathon 15 when water or microbial contamination is confirmed
Recommended Products
Based on your system condition, these are the recommended treatment products for preventative maintenance, corrective cleaning, and microbial contamination control.
- Best for ongoing maintenance
- First step treatment for early warning signs
- Supports cleaner system operation
- For escalation when issues persist
- Useful for severe restriction and blocked filters
- Supports faster recovery of flow



